SKU: 7798512621

Criticare nGenuity 8100EP1 Series

Sale price$2697.75 Regular price$2997.50
Save 10%

Pay in installments of $749.38 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 18 - Jul 23

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Criticare nGenuity 8100EP1 SeriesCriticare nGenuity 8100EP1 Patient Monitor The monitor comes with the following Printer SpO2 sensor Blood pressure hose with 3 blood pressure cuffs small, medium, and large sizes 3 lead ECG cable CO2 trap and sample line Power cord Battery Shipping most monitors ship out in three days. Please allows for one to two weeks Overview Flexible: Vital Signs Full featured monitors are available with many configurations including ETCO2 monitoring and

 

Criticare nGenuity 8100EP1 Patient Monitor




The monitor comes with the following



  • Printer
  • SpO2 sensor 
  • Blood pressure hose with 3 blood pressure cuffs small, medium, and large sizes
  • 3 lead ECG cable
  • CO2 trap and sample line
  • Power cord
  • Battery 

     
    Shipping most monitors ship out in three days. Please allows for one to two weeks


Overview


Flexible: Vital Signs Full-featured monitors are available with many configurations including ETCO2 monitoring and arrhythmia and ST analysis. They are compatible with EMR/HIS systems and Criticare’s VitalView central station. Cost-effective: The optional ETCO2 features a patented high capacity water trap with full occlusion clearing. The trap can be used on multiple patients so it costs less per procedure.
 

Service Includes:

  •  Monday thru Friday 9 am -5 pm Tech Support
  •  Monitor free Loaner during maintenance ($700 Value)
  •  Free Ground Shipping (available) 

 

Features

  • Standard features: ECG, ComfortCuff® NIBP, DOX® SpO2, Heart Rate, Temperature, Respiration and Nurse Call interface connection.
  • Optional features: End-tidal and inspired CO2, arrhythmia and ST analysis and integrated printer.
  • Optional CO2 monitoring incorporates CSI’s patented water trap design with full occlusion clearing.
  • Mini-Trends display of condensed tabular vital signs data to show recent monitoring activity.
  • Compatible with popular Electronic Medical Records (EMR) systems for both large and small offices.
  • Easy to read 10.4 inch TFT display.
  • Easy to learn, easy to use interface with simplified menus and dedicated function keys.
  • Attach quickly to wall mounts and roll stands.
     

Specifications 

ECG

Number of Leads:

3 – or 5 Lead

Lead View:

User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead);  I, II, or III (3-Lead)

Gain Selection:

x0.5, x1, x2, and x4

Frequency Response:

Diagnostic: 0.05 to 100 Hz (-3dB);

Monitor:

0.5 to 40 Hz (-3dB);

ST:

0.05 to 40 Hz (-3dB

Electrosurgery Protection:

Yes

Defibrillator Protection:

Yes

Pacer Detection/Rejection:

Yes

ST Accuracy:

 ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm

ST Range:

 -6.0 to 6.0 mm



 

NIBP

Technique:

Oscillometric measure upon inflation

Inflation Range:

Adult/Pediatric: 0 to 300 mmHg: Neonate: 0 to 150 mmHg

Measurement Cycle:

< 40 sec. typical; standard adult cuff

Auto. Measurement:

2, 3, 5, 10, 15, 30 min; 1, 2, 4 hour intervals

STAT Mode:

 5 minutes

of consecutive readings

Maximum Cuff Pressure:

 Adult/Pediatric:

300 mmHg; Neonate: 150 mmHg

Resolution:

1 mmHG

Transducer Accuracy:

±2 mmHg or ±2% of reading, whichever is greater, over full range

Clinical Accuracy:

Complies with AAMI

 

PULSE OXIMETRY

Range:

 1% to 99%

Resolution:

1%

Accuracy:

70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspecified

Method:

Dual wavelength LED

 

HEART RATE (PULSE)

Source:

User selectable: Smart, ECG, Pleth, NIBP

Range:

20 to 300 bpm (ECG, Pleth); 30 to 240 bpm (NIBP)

Accuracy:

±1 bpm or ±1% (ECG) whichever is greater

 

TEMPERATURE

Channels:

1

Probe:

YSI-400 and YSI-700 Series

Range, Accuracy:

68° to 113°F (20° to 45°C): ±0.1°C

Display Resolution:

0.1°C

 

RESPIRATION

Rate

6 to 150 bpm (ECG); 2 to 120 (CO2)

Resolution:

1 breath/min

Accuracy:

±1 breath/min

Source:

User selectable: Smart, CO2, ECG-TTI

 

CAPNOGRAPHY (CO2)

Units:

mmHg; kPa; Torr; Percent

Method:

Non-dispersive infrared; autocalibrating

N2O Compensation:

Manual (On/Off, user selectable

Range:

0 to 99 mmHg; 0 to 12.5%;

Flow, Sample Rate:

Sidestream; 200 ml/min

Accuracy:

 ±2 mmHg, ±0.3 volume %, ±0.3kPa, or ±2 Torr at 200 ml/min and respiratory rate equal or less than 120 bpm

Rise Time:

170 ms (10 to 90%) at 200 ml/min

 

ALARMS

Indication:

Audible; Visual

Silence:

Yes; 2 minutes or permanent

 

TRENDS

Memory:

24 hours at 30 second intervals with a NIBP reading

every three minutes

Display:

Tabular, Graphical

 

INTERFACE & DISPLAY

Keys:

9; membrane activated

Rotary Knob:

Push and rotate; 24 steps/turn

Screen:

10.4 inch active color TFT

Resolution:

Internal Display: 640 x 480;

External VGA Display: 640 x 480

Waveforms:

6, maximum

Waveform Types:

ECG Leads I, II, III, aVR,

AVL, AVF, V; Respiration; CO2; Pleth; ST

Histograms

Sweep Speed:

6.25, 12.5, 25, or 50 mm/sec

Languages:

English, Czech, French,

German, Italian, Polish, Portuguese,

Russian, Spanish, and Turkish

 

SYSTEM OUTPUTS

Nurse Call:

Contact switch; 3.5 mm phone

jack, 14 mm length

COM Port:

RS232 compatible, DB9 (Com 1)

Defib/Sync:

BNC connector

Video Port:

High density D-sub 15-pin

serial VGA compatible

 

PRINTER (OPTIONAL)

Type:

Thermal line printer

Paper Speed:

12.5, 25 or 50 mm/sec

 

PHYSICAL PROPERTIES

Weight:

14 lbs; 6.4 kg

Size:

11 in (H) x 13 in (W) x 10.3 (D); 28 cm

(H) x 33 cm (W) x 26.2 cm (D)

 

POWER REQUIREMENTS

Voltage:

100 to 240 VAC; 50/60 Hz

Power Consumption:

35 Watts, typical

Battery:

1 sealed lead acid

Battery Life:

3.0 hours, typical (2.5 hours w/

CO2

Recharge Time:

4.5 hours, typical

 

ENVIRONMENTAL

Operating Temperature:

59° to 95°F (15° to 35°C)

Storage Temperature:

23° to 122°F (-5° to 50°C)

Operating Humidity:

15% to 90%, noncondensing

 

CLASSIFICATION

Medical Device:

Class II Equipment (IIb EU)

Electrical Protection:

Class I Equipment

Degree of Protection:

Type CF, Defibrillator-proof

Protection Against Ingress:

IPX1

 

MONITOR CONFIGURATIONS

Catalog Number: 8100EP1

Standard with CO2, printer


 

Resources

OFFICE MANAGEMENT SOFTWARE COMPATIBILITY 
 CSI products are compatible with the following OMS products below. Contact software provider to confirm compatibility with specific configurations of Criticare monitors.

- Kodak WINOMS CS by Carestream Dental LLC
- TiME for OMS by Decision Base, Inc.
- U.S. HealthRecord powered by TeamLINKS, Inc.
- Oral Surgery-Exec® by DSN Practice Management Software
- OMSVision® by HenrySchein Practice Software
- Windent® by Carestream Dental LLC
- MD-REPORTS ProVation® Medical gMed Endosoft®

 

 

Accessories  |  Contact Us


Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 7798512621

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 9 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
B
Verified Purchase
BUGZ
Draper, US
★★★★★ 5
Low profile
Worked perfectly for draining oil from zero turn lawnmower. Even cons with a spare inlet plug
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 1, 2025
C
Verified Purchase
Claudia V.
Whiting, US
★★★★★ 5
1999 BMW 528i Fit and works like Original BMW-Pleasantly Surprised
1999 BMW 528i M52TU Engine. Pleasantly surprised and impressed. Everything fit as it should. Yes, one connector pipe took a bit more pressure to get it to "click" and lock, but it did click and lock..and better tight to insure no vacuum leak. Definitely works well and stopped the vacuum leak that old system had. Would recommend especially since price point might lead one to think that quality is not that good, but I'm glad I didn't spend any more on something else. Highly recommend.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 3, 2025
T
Verified Purchase
Trarell D. Williams
West Palm Beach, US
★★★★★ 5
Test fit to make sure it connects
When I revived it I thought it had looked a little too small until I compared it, I test fitted it and at first I thought it was a tad bit bigger but realized the more I pushed it in the more it went very tight fit and my car is running healthy. Installation is a pain but go to YouTube and search the “” the 50’s kid”” Who has two methods to getting them on, I went the intake removal route to replace additional parts.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 8, 2020
C
Verified Purchase
Cody Craddock
Omaha, US
★★★★★ 5
Cheap Replacement
These are an easy replacement for anyone who owns a BMW m52/m54 engine that has PCV issues. My car was burning about 1 quart every 1,000 miles. The parts are direct fit and install fairly easy. If there is resistance, lube the hole or o-ring up with some grease and it will slide in easier. Took me about 2 hours start to finish. My mechanic recommended that I remove the intake manifold to do the job. I don’t see how you could do it without removing the intake manifold. These parts probably won’t last as long as true BMW parts but on a 20 year old car I don’t see the benefit in using genuine BMW parts. Cheap stuff will suffice; worst case it doesn’t last quite as long.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 6, 2021
S
Verified Purchase
Slickster
Phoenix, US
★★★★★ 4
NOT TOO HARD TO INSTALL...
This CCV kit seems adequate. People say that because the hoses supplied with these kits are more brittle than the genuine BMW parts, these are tough to install... But they're really not. The ends on these hoses SWIVEL and you can sort of eyeball which way you need the fitting to be pointing BEFORE you put them on your manifold... They swivel, but they're tight and it takes a little force to turn them. ALSO, a little dab of silicone gel or a spray of silicone out of the can, into the fittings on these makes a world of difference when clicking them on... For the price, I highly recommend the kit.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 14, 2025

recommand products